Applied in intelligent manufacturing, packaging machinery, plastic machinery and other fields

  • Login
  • Register
Slot type photoelectric

Slot type photoelectric

1. Use a simple lead wire (standard wire length 2m); 2. Anti-sunlight type that is not affected by external light interference; 3. A variety of groove width shapes, suitable for various installation occasions, mark detection, liquid level detection and other applications; 4. The wire can be lengthened arbitrarily; 5. Designed products can have functions such as waterproof, oil-proof and dust-proof; 6. Waterproof products can be customized; 7. The patented red tail sleeve protection structure is adopted, and the soft line is unified as standard.
Including discontinued products

Reference model

Product model

  • F3C-06KS01-P/15D G02M

    F3C-06KS01-P/15D G02M

    Residual voltage: < 1.5vdc (load current 100mA, conductor 2m)

    Leakage current: <0.01mA No-load

    Current consumption: <10mA

    Standard test object: 6.5*6.5*1 (iron)

    Detection distance: 1mm

    Installation mode: Shielded type

  • F3C-06KS01-P R4M

    F3C-06KS01-P R4M

    Residual voltage: < 1.5vdc (load current 100mA, conductor 2m)

    Leakage current: <0.01mA No-load

    Current consumption: <10mA

    Standard test object: 6.5*6.5*1 (iron)

    Detection distance: 1mm

    Installation mode: Shielded type

  • F3C-06KS01-P R2M

    F3C-06KS01-P R2M

    Residual voltage: < 1.5vdc (load current 100mA, conductor 2m)

    Leakage current: <0.01mA No-load

    Current consumption: <10mA

    Standard test object: 6.5*6.5*1 (iron)

    Detection distance: 1mm

    Installation mode: Shielded type

  • F3C-06KS01-N2 R2M

    F3C-06KS01-N2 R2M

    Residual voltage: < 1.5vdc (load current 100mA, conductor 2m)

    Leakage current: <0.01mA No-load

    Current consumption: <10mA

    Standard test object: 6.5*6.5*1 (iron)

    Detection distance: 1mm

    Installation mode: Shielded type

  • F3C-06KS01-N/15D

    F3C-06KS01-N/15D

    Residual voltage: < 1.5vdc (load current 100mA, conductor 2m)

    Leakage current: <0.01mA No-load

    Current consumption: <10mA

    Standard test object: 6.5*6.5*1 (iron)

    Detection distance: 1mm

    Installation mode: Shielded type

  • F3C-06KS01-N R5M

    F3C-06KS01-N R5M

    Residual voltage: < 1.5vdc (load current 100mA, conductor 2m)

    Leakage current: <0.01mA No-load

    Current consumption: <10mA

    Standard test object: 6.5*6.5*1 (iron)

    Detection distance: 1mm

    Installation mode: Shielded type

  • F3C-06KS01-B R2M

    F3C-06KS01-B R2M

    Residual voltage: < 1.5vdc (load current 100mA, conductor 2m)

    Leakage current: <0.01mA No-load

    Current consumption: <10mA

    Standard test object: 6.5*6.5*1 (iron)

    Detection distance: 1mm

    Installation mode: Shielded type

  • F3C-06KN02-P R2M

    F3C-06KN02-P R2M

    Residual voltage: < 1.5vdc (load current 100mA, conductor 2m)

    Leakage current: <0.01mA No-load

    Current consumption: <10mA

    Standard test object: 6.5*6.5*1 (iron)

    Detection distance: 2mm

    Installation mode: Unshielded

  • F3C-06KN02-N2 R2M

    F3C-06KN02-N2 R2M

    Residual voltage: < 1.5vdc (load current 100mA, conductor 2m)

    Leakage current: <0.01mA No-load

    Current consumption: <10mA

    Standard test object: 6.5*6.5*1 (iron)

    Detection distance: 2mm

    Installation mode: Unshielded

  • F3C-06KN02-N/15D G02M

    F3C-06KN02-N/15D G02M

    Residual voltage: < 1.5vdc (load current 100mA, conductor 2m)

    Leakage current: <0.01mA No-load

    Current consumption: <10mA

    Standard test object: 6.5*6.5*1 (iron)

    Detection distance: 2mm

    Installation mode: Unshielded

  • F3C-06ES01-P2 R2M

    F3C-06ES01-P2 R2M

    Residual voltage: < 1.5vdc (load current 100mA, conductor 2m)

    Leakage current: <0.01mA No-load

    Current consumption: <10mA

    Standard test object: 6.5*6.5*1 (iron)

    Detection distance: 1mm

    Installation mode: Shielded type

  • F3C-06ES01-P R2M

    F3C-06ES01-P R2M

    Residual voltage: < 1.5vdc (load current 100mA, conductor 2m)

    Leakage current: <0.01mA No-load

    Current consumption: <10mA

    Standard test object: 6.5*6.5*1 (iron)

    Detection distance: 1mm

    Installation mode: Shielded type

  • F3C-06ES01-N2 R2M

    F3C-06ES01-N2 R2M

    Residual voltage: < 1.5vdc (load current 100mA, conductor 2m)

    Leakage current: <0.01mA No-load

    Current consumption: <10mA

    Standard test object: 6.5*6.5*1 (iron)

    Detection distance: 1mm

    Installation mode: Shielded type

  • F3C-06ES01-N/15D G02M

    F3C-06ES01-N/15D G02M

    Residual voltage: < 1.5vdc (load current 100mA, conductor 2m)

    Leakage current: <0.01mA No-load

    Current consumption: <10mA

    Standard test object: 6.5*6.5*1 (iron)

    Detection distance: 1mm

    Installation mode: Shielded type

  • F3C-06EN02-P R2M

    F3C-06EN02-P R2M

    Residual voltage: < 1.5vdc (load current 100mA, conductor 2m)

    Leakage current: <0.01mA No-load

    Current consumption: <10mA

    Standard test object: 6.5*6.5*1 (iron)

    Detection distance: 2mm

    Installation mode: Unshielded

  • F3C-06EN02-N2/15D G02M

    F3C-06EN02-N2/15D G02M

    Residual voltage: < 1.5vdc (load current 100mA, conductor 2m)

    Leakage current: <0.01mA No-load

    Current consumption: <10mA

    Standard test object: 6.5*6.5*1 (iron)

    Detection distance: 2mm

    Installation mode: Unshielded

  • F3C-06EN02-N2 R2M

    F3C-06EN02-N2 R2M

    Residual voltage: < 1.5vdc (load current 100mA, conductor 2m)

    Leakage current: <0.01mA No-load

    Current consumption: <10mA

    Standard test object: 6.5*6.5*1 (iron)

    Detection distance: 2mm

    Installation mode: Unshielded

  • F3C-06EN02-N/15D G02M

    F3C-06EN02-N/15D G02M

    Residual voltage: < 1.5vdc (load current 100mA, conductor 2m)

    Leakage current: <0.01mA No-load

    Current consumption: <10mA

    Standard test object: 6.5*6.5*1 (iron)

    Detection distance: 2mm

    Installation mode: Unshielded

  • F3C-06BS01-P R2M

    F3C-06BS01-P R2M

    Product model: F3C-06BS01-P R2M

  • F3C-05KS01-P/15D G02M

    F3C-05KS01-P/15D G02M

    Residual voltage: < 1.5vdc (load current 100mA, conductor 2m)

    Leakage current: <0.01mA No-load

    Current consumption: <10mA

    Standard test object: 5*5*1 (iron)

    Detection distance: 1mm

    Installation mode: Shielded type

  • F3C-05KS01-P R2M

    F3C-05KS01-P R2M

    Residual voltage: < 1.5vdc (load current 100mA, conductor 2m)

    Leakage current: <0.01mA No-load

    Current consumption: <10mA

    Standard test object: 5*5*1 (iron)

    Detection distance: 1mm

    Installation mode: Shielded type

  • F3C-05KS01-N/15D G03M

    F3C-05KS01-N/15D G03M

    Residual voltage: < 1.5vdc (load current 100mA, conductor 2m)

    Leakage current: <0.01mA No-load

    Current consumption: <10mA

    Standard test object: 5*5*1 (iron)

    Detection distance: 1mm

    Installation mode: Shielded type

  • F3C-05KS01-N/15D G02M

    F3C-05KS01-N/15D G02M

    Residual voltage: < 1.5vdc (load current 100mA, conductor 2m)

    Leakage current: <0.01mA No-load

    Current consumption: <10mA

    Standard test object: 5*5*1 (iron)

    Detection distance: 1mm

    Installation mode: Shielded type

  • F3C-05KS01-N R4M

    F3C-05KS01-N R4M

    Residual voltage: < 1.5vdc (load current 100mA, conductor 2m)

    Leakage current: <0.01mA No-load

    Current consumption: <10mA

    Standard test object: 5*5*1 (iron)

    Detection distance: 1mm

    Installation mode: Shielded type

  • F3C-05KS01-N R3M

    F3C-05KS01-N R3M

    Residual voltage: < 1.5vdc (load current 100mA, conductor 2m)

    Leakage current: <0.01mA No-load

    Current consumption: <10mA

    Standard test object: 5*5*1 (iron)

    Detection distance: 1mm

    Installation mode: Shielded type

  • F3C-05KS01-N R2M 5V

    F3C-05KS01-N R2M 5V

    Residual voltage: < 1.5vdc (load current 100mA, conductor 2m)

    Leakage current: <0.01mA No-load

    Current consumption: <10mA

    Standard test object: 5*5*1 (iron)

    Detection distance: 1mm

    Installation mode: Shielded type

  • F3C-05KS01-N R2.6M

    F3C-05KS01-N R2.6M

    Residual voltage: < 1.5vdc (load current 100mA, conductor 2m)

    Leakage current: <0.01mA No-load

    Current consumption: <10mA

    Standard test object: 5*5*1 (iron)

    Detection distance: 1mm

    Installation mode: Shielded type

  • F3C-05KS01-N F0.3M

    F3C-05KS01-N F0.3M

    Residual voltage: < 1.5vdc (load current 100mA, conductor 2m)

    Leakage current: <0.01mA No-load

    Current consumption: <10mA

    Standard test object: 5*5*1 (iron)

    Detection distance: 1mm

    Installation mode: Shielded type

  • F3C-05KS0.5-N R2M

    F3C-05KS0.5-N R2M

    Residual voltage: < 1.5vdc (load current 100mA, conductor 2m)

    Leakage current: <0.01mA No-load

    Current consumption: <10mA

    Standard test object: 5*5*1 (iron)

    Detection distance: 1mm

    Installation mode: Shielded type

  • F3C-05ES01-P2 R2M

    F3C-05ES01-P2 R2M

    Residual voltage: < 1.5vdc (load current 100mA, conductor 2m)

    Leakage current: <0.01mA No-load

    Current consumption: <10mA

    Standard test object: 5*5*1 (iron)

    Detection distance: 1mm

    Installation mode: Shielded type

Tel
400-0731-388(china)
Consult
Consult
WeChat
WeChat
WeChat
Top
Top